Commissioning guide

SC1000 / SC2000 quick start

Commission an SC1000 or SC2000 in five stages: connection, image, inspection, PLC result and restart. This guide defines what to check at each stage. Use the manual and SCMVS release supported by your exact camera model for connector details and menu names. A successful bench test is the starting point for production validation.

1. Power and network

Record the camera model, firmware and SCMVS version. With power disconnected, wire the supply and signals according to that model’s pinout; an Ethernet port does not establish PoE support. Connect the camera and setup PC on an isolated test network or a network agreed with IT. For an illustrative static configuration, a PC at 192.168.10.10 and camera at 192.168.10.20 with mask 255.255.255.0 share a subnet; both addresses must be unused. Discover the camera in the supported software and confirm its serial number. Pass this stage when you can reconnect to the same device. If discovery fails, check power indication, physical link and addressing before changing inspection settings.

2. Obtain a usable live image

Connect in SCMVS and start continuous acquisition for setup. Put a representative product at the production working distance. Adjust focus and aperture where the hardware permits, then set lighting and exposure so the inspected feature is visible without clipping important bright areas. Check the corners as well as the image centre. Freeze automatic exposure or gain adjustments for a controlled trial unless the application explicitly needs them. Test the fastest expected movement: maximum exposure equals allowed object-space blur divided by speed. For illustration, 0.1 mm at 500 mm/s gives 0.2 ms; this is an exposure budget, not proof that the available light is sufficient. Pass when the feature remains distinguishable across the agreed positions and surface variations.

3. Build and challenge one inspection

Choose one supported presence or measurement tool. If the product can move in the image, first locate it and reference the inspection region to that position using the supported coordinate function. For an illustrative cap-presence check, define the region on a correctly capped product, then compare capped, missing-cap and partially seated examples. Record each tool value and expected decision before setting limits. Keep separate products for validation; reusing only the setup examples hides variation. A missing position result must produce an invalid inspection or reject according to the agreed machine behaviour, never reuse the previous pass. Pass this stage when the recorded decisions meet the agreed missed-defect and false-reject limits on the independent sample set.

4. Associate each result with its trigger

Agree the signal sequence with the PLC engineer using the I/O or protocol supported by the exact model. The PLC checks readiness, issues a trigger and waits for a new result within a defined timeout. Use a result counter or an agreed result-valid/acknowledge sequence to distinguish a new decision from a retained value. Confirm which controller clears or acknowledges the result before another cycle. Exercise pass, fail, no valid image, trigger while busy and cable loss. Observe the actual PLC inputs or messages; a green indicator in SCMVS alone does not validate the connection. Record the longest measured trigger-to-result time under the test conditions, and prove that a timeout cannot be treated as a pass.

5. Save, restart and hand over

Save the configuration using the supported procedure and retain an external backup with model, firmware, SCMVS version, network settings and sample results. Restart the camera and confirm that the intended inspection loads and produces a fresh result from the PLC trigger. Record who can change limits and who restores the backup after replacement. Budget commissioning time, operator training and spare components alongside the camera price. If the trial exposes processing, interface or multi-camera limits, compare architectures before expanding the project. Related timing guidance:Trigger-to-result timing.

Continue with the detailed instructions in theSCMVS manual. Compare models underCameras. For help, send your model, software version, sample images and the stage that fails viaContact.