20250519200143912.png

MV-ID3000

1280 × 1024 · ID3013PM · 06M · WBN

MV-ID3013PM-06M-WBN

Smart Code Reader

MV-ID3000 is a fixed smart code-reader family with 25 existing combinations of resolution, reader platform, optical configuration and illumination configuration. Code size, working distance, optical configuration, lighting and product movement determine the suitable reader.
Beschikbare configuraties
  • mv-id3016xm-25m-rbn — 1408 × 1200 · ID3016XM · 25M · RBN
  • mv-id3050pm-08m-wbn — 2432 × 2048 · ID3050PM · 08M · WBN
  • MV-ID3013PM-06M-WBN — 1280 × 1024 · ID3013PM · 06M · WBN
  • MV-ID3013PM-12M-WBN — 1280 × 1024 · ID3013PM · 12M · WBN
  • mv-id3050pm-12m-wbn — 2432 × 2048 · ID3050PM · 12M · WBN
  • MV-ID3013PM-15M-WBN — 1280 × 1024 · ID3013PM · 15M · WBN
  • MV-ID3016PM-06M-WBN — 1408 × 1200 · ID3016PM · 06M · WBN
  • MV-ID3016PM-12M-WBN — 12M · WBN · 1408 × 1200 · ID3016PM
  • MV-ID3016PM-15M-WBN — 1408 × 1200 · ID3016PM · 15M · WBN
  • MV-ID3016XM-08M-RBN — 1408 × 1200 · ID3016XM · 08M · RBN
  • MV-ID3016XM-12M-RBN — 1408 × 1200 · ID3016XM · 12M · RBN
  • MV-ID3016XM-16M-RBN — 1408 × 1200 · ID3016XM · 16M · RBN
  • MV-ID3016XM-16L-RBN — 1408 × 1200 · ID3016XM · 16L · RBN
  • MV-ID3030XM-08M-RBN — 2048 × 1536 · ID3030XM · 08M · RBN
  • MV-ID3030XM-12M-RBN — 2048 × 1536 · ID3030XM · 12M · RBN
  • MV-ID3030XM-16M-RBN — 2048 × 1536 · ID3030XM · 16M · RBN
  • MV-ID3030XM-25M-RBN — 2048 × 1536 · ID3030XM · 25M · RBN
  • MV-ID3030XM-16L-RBN — 2048 × 1536 · ID3030XM · 16L · RBN
  • MV-ID3050XM-08M-RBN — 2432 × 2048 · ID3050XM · 08M · RBN
  • MV-ID3050XM-12M-RBN — 2432 × 2048 · ID3050XM · 12M · RBN
  • MV-ID3050XM-16M-RBN — 2432 × 2048 · ID3050XM · 16M · RBN
  • mv-id3050pm-16m-wbn — 2432 × 2048 · ID3050PM · 16M · WBN
  • MV-ID3050XM-25M-RBN — 2432 × 2048 · ID3050XM · 25M · RBN
  • mv-id3050pm-25m-wbn — 2432 × 2048 · ID3050PM · 25M · WBN
  • MV-ID3050XM-16L-RBN — 2432 × 2048 · ID3050XM · 16L · RBN

Select variant

SKU: MV-ID3013PM-06M-WBN

Selection question

Keep code reading stable across distance, motion and surface variation

No-reads lead to rescans, reject handling and interruptions in traceability. The suitable reader depends on code size and quality, field of view, working distance, movement, surface reflections and the required result time.

Select platform and optics together

Start with the required resolution and reader platform. Then choose the exact optical and illumination configuration. Focal length, focus method, lens mount, frame rate, interface and I/O remain in the specification table for each SKU.

Resolution

Four pixel dimensions are available. Calculate the smallest code element in pixels at the full required field of view and retain margin for position and focus variation.

Reader platform

The six platforms separate sensor, housing, optical architecture and I/O implementation. Use the selected SKU specifications for the exact physical and electrical details.

Optical configuration

Codes such as 06M, 16L and 25M are exact Hikrobot configuration codes. The linked focal length, lens mount and focus method depend on the platform and must be checked in the selected SKU table.

Illumination configuration

WBN and RBN are exact supplied configuration codes. Their practical illumination arrangement varies by platform. Confirm code contrast and reflections with the actual surface and mounting angle.

The selector contains only the 25 live SKUs. It does not generate unavailable combinations. Six variants currently have no verified exact product media.

Test the full trigger-to-result chain

Set measurable acceptance criteria and use representative production samples before ordering the final configuration.

  • Include the smallest codes, lowest contrast, damaged marks and reflective surfaces.
  • Test minimum and maximum working distance, orientation variation, line speed and motion blur.
  • Measure successful reads, no-reads and false reads over a defined sample and after a restart or changeover.
  • Verify trigger timing, PLC communication, reject handling and recovery after a communication interruption.

Inputs for the business case

Use measured process data. Nominal reader specifications do not establish throughput or payback.

  • Manual rescans, operator interventions, line stops and traceability exceptions per shift.
  • Mounting, lighting, cabling, PLC integration, reject handling and validation costs.
  • Cleaning, changeover and maintenance time for the complete reading station.
Discuss an MV-ID3000 reading trial

Specifications

BrandHikrobot
CategoryFixed smart code reader
ModelMV-ID3013PM-06M-WBN
Illumination configurationWBN
Optical configuration06M
Reader platformID3013PM
Resolution1280 × 1024
Illumination configurationWBN
Optical configuration06M
Reader platformID3013PM
Resolution1280 × 1024
CertificationCE, RoHS, KC
Client softwareIDMVS
Communication protocolSmartSDK, TCP Client, TCP Server, Serial, FTP, Profinet, Ethernet/IP, MELSEC/SLMP, ModBus, UDP, Fins, Modbus RTU
Data interfaceFast Ethernet (100 Mbit/s)
Digital I/O17-pin M12 connector provides power and I/O, including non-isolated input (LineIn 0/1/2) × 3, non-isolated output (LineOut 3/4/5) × 3, RS-232 × 1. Supports device triggering via pressing button on top.;17-pin M12 connector provides power and I/O, including isolated input (LineIn 0/1/2) × 3, isolated output (LineOut 3/4/5) × 3, RS-232 × 1. Supports device triggering via pressing button on top.
Dimensions65.2 mm × 65.2 mm × 47 mm (2.6" × 2.6" × 1.9")
Exposure time35 μs to 1 sec
Field of view46° (H) × 37° (V)
Focal length6 mm
Gain0 dB to 28 dB
Humidity20% RH to 95% RH (no condensation)
IndicatorPower indicator (PWR), network indicator (LNK), status indicator (STS), result indicator (OK/NG)
Ingress protectionIP67 (under proper installation of waterproof lens cap)
Lens capHalf-polarized lens cap by default. Transparent, fully-polarized, diffused, and long-wave IR lens caps are optional.
Lens mountM12-mount, mechanical focus supported
Light sourceWhite light by default. Red/blue/IR/UV light is optional.
Max. frame rate60 fps
Max. reading speed84 codes/sec
Mono/colorMono
Pixel size4 μm × 4 μm
Power consumptionAvg.: 9 W @ 24 VDC (light source enabled) Max.: 48 W @ 24 VDC (light source enabled)
Power supply24 VDC
Sensor size1/2.7"
Sensor typeGlobal shutter, mono, 1/2.7", 4 μm × 4 μm
Shell materialADC12
Shock resistanceDevice only, 30 g / 11 ms, half-sine wave, 500 shocks per axis (6 directions) (IEC 60068-2-27\GB/T 2423.5-2019)
Symbologies1D codes: Code 39, Code 93, Code 128, CodaBar, EAN 8, EAN 13, UPCA, UPCE, ITF 14, ITF 25, Matrix 25, MSI, China Post, Code 11, and Industrial 25 2D matrix codes: QR Code (GS1-QR included), Data Matrix (GS1-DM included), MicroQR, AZTEC, HanXin, Maxi code Stacked codes: PDF417, MicroPDF417
TemperatureWorking temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 70 °C (–22 °F to 158 °F)
Vibration resistanceDevice only: 10 Hz to 55 Hz, 1.5 mm full amplitude, 2 hours per axis (X/Y/Z) (IEC 60068-2-6:2007\GB/T 2423.10-2019)
WeightApprox. 280 g (0.6 lb.)

MV-ID3000 specification questions

How should the required resolution be calculated?

Calculate how many pixels cover the smallest code element at the full required field of view. Confirm the result with real codes and include margin for focus, position, print quality and motion variation.

What do optical codes such as 16M and 16L mean?

They are exact Hikrobot configuration codes. Their focal length, lens mount and focus method are platform-dependent. Check those fields in the specifications of the selected SKU.

What is the difference between WBN and RBN?

They identify different supplied illumination configurations. The detailed arrangement varies by reader platform, so use the selected SKU’s light-source specification and validate it on the actual code surface.

Why are interface and certification not selector axes?

The live range uses Fast Ethernet, while textual differences in imported interface labels describe the same 100 Mbit/s connection. Certification remains SKU information and does not distinguish the existing purchasing combinations.

Does maximum frame rate equal reading throughput?

No. Throughput also depends on exposure, decoding time, code count and quality, trigger timing and result communication. Measure the complete cycle with the intended PLC.

Which conditions belong in the acceptance test?

Include code type and size, marking method, surface, working-distance range, field of view, speed, orientation, ambient light, contamination, trigger timing, communication and reject handling.

Jeroen van den Berg

A question about a product?

Jeroen can help you choose the right model for your application.

Ask your question

Compare products

20250519200143912.png
Productfamilie
MV-ID3000
Geselecteerde variant
1280 × 1024 · ID3013PM · 06M · WBN
MV-ID3013PM-06M-WBN