20250519200404959.png

MV-ID2000

ID2013EMI · 03N · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard

MV-ID2013EMI-03N-RBN

Smart Code Reader

MV-ID2000 is a fixed smart code-reader family with 72 existing combinations of reader platform, optical configuration, illumination, polarization, interface, I/O and filter. Code size, working distance, optical configuration, lighting and product movement determine the suitable reader.
Beschikbare configuraties
  • mv-id2013em-05-wbn — ID2013EM · 05 · White · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05-rbn — ID2013EM · 05 · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2004m-16t-rbn — ID2004M · 16T · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2013EMI-03N-RBN — ID2013EMI · 03N · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2004m-06s-rbn — ID2004M · 06S · Red · Standard · Fast Ethernet · Standard · Standard
  • mv-id2013em-03n-rbn — ID2013EM · 03N · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05h-rbn — ID2013EM · 05H · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05n-rbp — ID2013EM · 05N · Red · Polarized · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05-rbn-u — ID2013EM · 05 · Red · Standard · USB 3.0 · Standard · Standard
  • mv-id2013em-05-rbp-s — ID2013EM · 05 · Red · Polarized · Fast Ethernet, RS-232 and DC terminal · Isolated · Standard
  • mv-id2004m-06s-wbn — ID2004M · 06S · White · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2013EMI-03N-RBP — ID2013EMI · 03N · Red · Polarized · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-03n-rbp — ID2013EM · 03N · Red · Polarized · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05-rbp — ID2013EM · 05 · Red · Polarized · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05-wbp — ID2013EM · 05 · White · Polarized · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05h-rbp — ID2013EM · 05H · Red · Polarized · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
  • mv-id2013em-05-rbn-s — Standard · ID2013EM · 05 · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Isolated
  • MV-ID2013EMI-03N-RBP-S — ID2013EMI · 03N · Red · Polarized · Fast Ethernet, RS-232 and DC terminal · Isolated · Standard
  • MV-ID2013EMI-03N-WBP-S — ID2013EMI · 03N · White · Polarized · Fast Ethernet, RS-232 and DC terminal · Isolated · Standard
  • mv-id2013em-05-rbp-u — ID2013EM · 05 · Red · Polarized · USB 3.0 · Standard · Standard
  • mv-id2013em-05-wbn-u — ID2013EM · 05 · White · Standard · USB 3.0 · Standard · Standard
  • mv-id2013em-05-wbp-u — ID2013EM · 05 · White · Polarized · USB 3.0 · Standard · Standard
  • mv-id2013em-05-rbn-su — ID2013EM · 05 · Red · Standard · USB 3.0 · Isolated · Standard
  • mv-id2013em-05-rbp-su — ID2013EM · 05 · Red · Polarized · USB 3.0 · Isolated · Standard
  • mv-id2013em-05h-rbn-s — ID2013EM · 05H · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Isolated · Standard
  • mv-id2013em-05h-rbn-u — ID2013EM · 05H · Red · Standard · USB 3.0 · Standard · Standard
  • mv-id2013em-05n-rbn-s — ID2013EM · 05N · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Isolated · Standard
  • mv-id2013em-05n-rbn-u — ID2013EM · 05N · Red · Standard · USB 3.0 · Standard · Standard
  • mv-id2013em-05h-rbn-su — ID2013EM · 05H · Red · Standard · USB 3.0 · Isolated · Standard
  • mv-id2013em-05n-rbn-su — ID2013EM · 05N · Red · Standard · USB 3.0 · Isolated · Standard
  • MV-ID2004M-06S-WBN-U — ID2004M · 06S · White · Standard · USB 3.0 · Standard · Standard
  • MV-ID2013M-06S-WBP — ID2013M · 06S · White · Polarized · Fast Ethernet · Standard · Standard
  • mv-id2013m-06s-bbn — ID2013M · 06S · Blue · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2013M-16S-RBN — ID2013M · 16S · Red · Standard · Fast Ethernet · Standard · Standard
  • mv-id2013m-06s-rbn — ID2013M · 06S · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2013M-25S-RBN — ID2013M · 25S · Red · Standard · Fast Ethernet · Standard · Standard
  • mv-id2013m-06s-rbp — ID2013M · 06S · Red · Polarized · Fast Ethernet · Standard · Standard
  • mv-id2013m-06s-wbn — ID2013M · 06S · White · Standard · Fast Ethernet · Standard · Standard
  • mv-id2013m-06s-rbn-yag — ID2013M · 06S · Red · Standard · Fast Ethernet · Standard · YAG filter
  • mv-id2016m-06s-bbn — ID2016M · 06S · Blue · Standard · Fast Ethernet · Standard · Standard
  • mv-id2016m-06s-rbn — ID2016M · 06S · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2013XM-05M-RBN-U — ID2013XM · 05M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • mv-id2016m-06s-wbn — ID2016M · 06S · White · Standard · Fast Ethernet · Standard · Standard
  • mv-id2016m-06t-rbp — ID2016M · 06T · Red · Polarized · Fast Ethernet · Standard · Standard
  • MV-ID2013XM-08M-RBN-U — ID2013XM · 08M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • mv-id2016m-10t-rbp — ID2016M · 10T · Red · Polarized · Fast Ethernet · Standard · Standard
  • MV-ID2013XM-12M-RBN-U — ID2013XM · 12M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • mv-id2016m-16s-rbn — ID2016M · 16S · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2013XM-16M-RBN-U — ID2013XM · 16M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2013XM-08L-RBN-U — ID2013XM · 08L · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • mv-id2016m-25s-rbn — ID2016M · 25S · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2013XM-12L-RBN-U — ID2013XM · 12L · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2013XM-16L-RBN-U — ID2013XM · 16L · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2016M-06S-BBN-U — ID2016M · 06S · Blue · Standard · USB 3.0 · Standard · Standard
  • MV-ID2016M-06S-RBN-U — ID2016M · 06S · Red · Standard · USB 3.0 · Standard · Standard
  • MV-ID2016M-06S-WBN-U — ID2016M · 06S · White · Standard · USB 3.0 · Standard · Standard
  • MV-ID2016M-16T-RBN — ID2016M · 16T · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-05M-RBN — ID2023XM · 05M · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-05M-RBN-U — ID2023XM · 05M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2023XM-08M-RBN — ID2023XM · 08M · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-08M-RBN-U — ID2023XM · 08M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2023XM-12M-RBN — ID2023XM · 12M · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-12M-RBN-U — ID2023XM · 12M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2023XM-16M-RBN — ID2023XM · 16M · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-16M-RBN-U — ID2023XM · 16M · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2023XM-08L-RBN — ID2023XM · 08L · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-08L-RBN-U — ID2023XM · 08L · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2023XM-12L-RBN — ID2023XM · 12L · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-12L-RBN-U — ID2023XM · 12L · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2023XM-16L-RBN — ID2023XM · 16L · Red · Standard · Fast Ethernet · Standard · Standard
  • MV-ID2023XM-16L-RBN-U — ID2023XM · 16L · Red · Standard · USB 2.0 with DC power · Standard · Standard
  • MV-ID2018L-10S — ID2018L · 10S · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard

Select variant

SKU: MV-ID2013EMI-03N-RBN
Prijs op aanvraag

Selection question

Match the reader to the code, distance and line connection

Unstable code reading causes manual rescans, stops and uncertain traceability. The result depends on code size and quality, surface reflections, movement, working distance and how the reader exchanges results with the control system.

Use the platform and optical code as the starting point

MV-ID2000 contains several hardware platforms and optical configurations. After that first choice, select illumination, polarization, data interface, I/O isolation and any YAG filter. Resolution, focal length, lens mount, frame rate and working-distance data remain in the specification table for the selected SKU.

What the selector choices change

Reader platform

The eight platform values separate sensor resolution, housing, processing and optical architecture. Compare the selected SKU specifications; a platform name alone does not define the working range.

Optical configuration

Codes such as 03N, 06S and 08L are exact Hikrobot model codes. Their focal length, lens mount, focus method and field of view vary by platform. Use the selected SKU table for those physical values.

Illumination and polarization

Red, white and blue light interact differently with colored materials. Polarized versions can reduce direct reflections on suitable surfaces. Confirm contrast with the actual code, substrate and protective film.

Data interface

The existing range includes Fast Ethernet, Fast Ethernet with RS-232 and a DC terminal, USB 2.0 with DC power, and USB 3.0. Check cable length, power delivery, protocol and PLC or PC connection together.

I/O configuration

The isolated option identifies models with isolated I/O. Confirm input and output count, electrical levels and trigger timing in the selected SKU documentation.

Optical filter

The YAG-filter SKU is a specific existing model. Treat the filter as an optical compatibility decision and validate it with the marking process and illumination wavelength.

The selector keeps only the 72 combinations that exist as live SKUs. It does not generate a full matrix of platforms, optics, colors and interfaces.

Test the complete trigger-to-result chain

Use representative codes at the limits of the process and agree the acceptance criteria before ordering the final reader.

  • Include the smallest codes, lowest contrast, damaged marks, reflective surfaces and expected orientation variation.
  • Test minimum and maximum working distance, line speed, motion blur and ambient-light changes.
  • Measure successful reads, no-reads and false reads over a defined sample, including restart and changeover behaviour.
  • Verify trigger, result timing, PLC or PC communication, reject handling and recovery after a communication interruption.

Inputs for the business case

Use measured production data. Reader specifications alone do not establish throughput or payback.

  • Manual rescans and operator interventions per shift, with time per event.
  • Line stops, recirculation, false rejects and traceability exceptions caused by no-reads.
  • Mounting, cabling, PLC or PC integration, safety and validation effort.
  • Cleaning, changeover and maintenance time, plus the cost of representative trials.
Discuss a code-reading trial

Specifications

BrandHikrobot
CategoryFixed smart code reader
ModelMV-ID2013EMI-03N-RBN
Data interfaceFast Ethernet, RS-232 and DC terminal
Optical filterStandard
I/O configurationStandard
Light sourceRed
Optical configuration03N
PolarizationStandard
Reader platformID2013EMI
Data interfaceFast Ethernet, RS-232 and DC terminal
Optical filterStandard
I/O configurationStandard
Light sourceRed
Optical configuration03N
PolarizationStandard
Reader platformID2013EMI
Aiming systemGreen LED
CertificationCE, RoHS, KC
Client softwareIDMVS
Communication protocolSmartSDK, TCP Client, Serial, FTP, TCP Server, UDP, Profinet, Ethernet/IP
Dimensions45 mm × 43 mm × 25 mm (1.8" × 1.7" × 1.0")
Exposure time60 μs to 6000 μs
Field of view70°(H) × 58°(V)
Focal length2.48 mm
Focus distance70 mm
Humidity20% RH to 95% RH (no condensation)
Ingress protectionIP54
Lens mountM5.5-mount
Max. frame rate50 fps
Max. reading speed30 codes/sec
Mono/colorMono
Pixel size6.9 μm × 6.9 μm
Power consumptionAvg.: 2.5 W @ 12 VDC to 24 VDC Max.: 5 W @ 12 VDC to 24 VDC
Power supply12 VDC to 24 VDC
Resolution1280 × 1024
Sensor size1/2.9"
Sensor typeCMOS, global shutter, mono, 1/4", 2.7 μm × 2.7 μm
Symbologies1D codes: Code 39, Code 93, Code 128, EAN8, EAN13, ITF 14, ITF 25, CodaBar, UPCA, UPCE 2D codes: QR Code, Data Matrix, MicroQR, AZTEC, HanXin Stacked codes: PDF417
TemperatureWorking temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 70 °C (–22 °F to 158 °F)
WeightApprox. 68.5 g (0.2 lb.)

MV-ID2000 specification questions

Why is resolution not a selector axis?

Resolution is tied to the reader platform in the existing range. Selecting a platform and optical configuration identifies a real SKU; the exact pixel dimensions remain visible in that SKU’s specifications.

What does the optical configuration code mean?

It is the exact Hikrobot model code carried in the SKU. Its physical meaning is platform-dependent. Use the selected SKU’s focal length, lens mount, focus method, field of view and working-distance specifications for engineering decisions.

When should a polarized model be tested?

Test polarization when direct reflections from glossy labels, films or parts reduce code contrast. Its effect depends on surface angle and illumination geometry, so compare captured images from the real installation.

What changes between Ethernet and USB models?

The physical connection, available protocols, power arrangement and practical cable distance change. Some Ethernet models also expose RS-232 and a DC terminal; USB 2.0 and USB 3.0 models have different power and host requirements.

Does maximum frame rate equal reading throughput?

No. Reading throughput also depends on exposure, decoding time, code quality, number of codes, trigger timing and result communication. Validate the complete cycle with the intended PLC or PC.

Which data should be fixed before selecting a SKU?

Record code type and size, substrate, marking method, working-distance range, field of view, object speed, orientation variation, ambient light, required result timing, interface, I/O levels and available power.

Jeroen van den Berg

A question about a product?

Jeroen can help you choose the right model for your application.

Ask your question

Compare products

20250519200404959.png
Productfamilie
MV-ID2000
Geselecteerde variant
ID2013EMI · 03N · Red · Standard · Fast Ethernet, RS-232 and DC terminal · Standard · Standard
MV-ID2013EMI-03N-RBN